IO-Link Master 8-EIP/Modbus Eight channel IO-Link Master to EtherNet/IP™/Modbus TCP, machine or panel mount, IP67 housing
- Eight port IO-Link Master to Modbus TCP and EtherNet/IP™
- Rugged IP67 housing desing for harsh environments, M12 connectors allowing up to eight sensor or actuator connections on one master block
- MultiLink™ – Simultaneously provides IO-Link device access to multiple controllers
- Modbus TCP and EtherNet/IP™ access to IO-Link process, event and service data
- Modbus TCP and EtherNet/IP™ Class 1 (Implicit) and Class 3 (Explicit) interfaces
- HMI, SCADA, and PLC access to IO-Link ISDU blocks without complex programming
- EDS files and sample programs
- Powerful web GUI for configuration and diagnostics, including:
- IO-Link device management using the IO-Link device manufacturers IODD file for easy device configuration
- Automatic data storage (upload and download)
- Manual data storage (upload and download)
- Device validation
- Data validation
- Wide operating temperature (-25° to +60°C)
- Additional digital input on every port
- IO-Link V1.0 and V1.1 compatibility
- IO-Link COM1, COM2 and COM3 (230K baud rate) support
Hardware
- Network Interface10/100BASE-TX
- EnclosureMolded ABS (potted)
- Ingress Protection RatingIP67
- Installation and Grounding MethodMachine or panel mount
Two-hole M4 or #8 screws - Network ProtocolsEtherNet/IP™, Modbus/TCP (slave)
- Connectors (M12)8 - IO-Link
2 - Ethernet
2 - Power - LED IndicatorsPower, Module Status, Network Status, IO-Link, DI and Ethernet Port Status
- Dimensions8.35" x 2.56" x 1.18"
212 x 65 x 30 mm - Product Weight1.0 lb
454 kg
IO-Link Interface Specifications
- Connector TypeFemale, M12, A-coded, 5-pin
- Number of Ports8
- IO-Link VersionSupport V1.0 and V1.1
- Connector PinoutPin 1 = L+
Pin 2 = DI
Pin 3 = L-
Pin 4 = C/Q
Pin 5 = Not Connected
- Configurations per PortIO-Link = 1
DI (SIO mode) = 1
DO (SIO mode) = 1
DI (dedicated) = 1 - IO-Link Mode Transfer Rates4.8K (COM1)
38.4K (COM2)
230.4K (COM3) - Baud rate recognitionAutomatic
- Output Current on IO-Link Connectors (Ports 1-8)
- C/Q on Pin 4Vs on Pins 1, 3
- 200mA (Maximum)1.6mA* (Maximum)
- 200mA (Maximum)500mA* (Maximum)
- Short Circuit ProtectionYes
- Cable Length (Maximum)30 m
Digital Inputs C/Q (SIO Mode Using IO-Link Ports)
- Sensor Current Load (Maximum)200mA
- Input CharacteristicsIEC 61131-2 Type 1 and Type 3 Compliant
- Short-Circuit and Overload protectionYes
- Short-Circuit proofYes
- Input Current LimitationYes
- C/Q Input ThresholdLow: 8.0 - 11.5V
High: 10.5 - 13.0V
Digital Outputs C/Q (SIO Mode Using IO-Link Ports)
- Actuator Current Load (Maximum)200mA
- Input CharacteristicsIEC 61131-2 Type 1 and Type 3 Compliant
- Short-Circuit and Overload ProtectionYes
- Short-Circuit ProofYes
- Input Current LimitationYes
- Output FunctionPNP/NPN
Digital Inputs (Only) Specifications
- Sensor Current Load (Maximum)200mA
- Input CharacteristicsIEC 61131-2 Type 1 and Type 3 Compliant
- Short-Circuit and Overload ProtectionYes
- Short-Circuit ProofYes
- Input Current LimitationYes
- DI Input ThresholdLow: 5.2 - 6.4V
High: 6.8 - 8.0V
Ethernet/IP Interface Specifications
- Supported PLCsIncluding but not limited to:
• Control Logix
• Compact Logix
• RSLogix
• SLC 500
• PLC5
• MicroLogix
• Other Class 1 or Class 3 EtherNet/IP PLCs may be supported - ISDU Read & WritesUp to 40 individual commands in one EtherNet/IP message
- ISDU CommandsSelectable byte swapping (none, 16-bit, or 32-bit)
Selectable payload sizes (4 to 232 bytes)
ISDU block index
ISDU sub-index
Length of read or write
Data payload - Web Page ConfigurationProvides the following capabilities:
• Port configuration for ISDU Data, Process Data, Transfer Mode, Read/Write, Write PDI to Tag/File, and Read PDO from Tag/File.
• EtherNet/IP configuration:
• Time to Live (TTL) Network Value
• Multicast IP Address Allocation Control
• User-Defined Number of Multicast IP Addresses
• User-Defined Multicast Starting IP Address
• Session Encapsulation Timeout - DiagnosticsYes
- Electronic Data Sheets (EDS)Yes
- Sample PLC ProgramsYes
IO-Link Master Features
- Data StorageAutomatic or Manual - Upload and/or Download
- Device ValidationYes
- Data ValidationYes
- Powerful Web InterfaceProvides the following capabilities:
• Firmware upgradable
• Password protected with Admin, Operator, and User accounts
• ISDU batch handling
• Load IODD files to configure the IO-Link device
• IODD Handler parses xml files making them readable and configurable
• Log files - Upgradable FirmwareYes (Web page or using PortVision DX)
- Remote ParameterizationYes
- Mobile App SupportSimplify monitoring of control system Process and Service Data using simple standard clients available for free in Google Play and Apple App Store
Electrical Specifications
- Input Voltage Rance20-30VDC / 4A (Maximum)
- Power Supply In
- Vs12A (Maximum)
- Va10A (Maximum)
We will inform you if the price of this product will be changed according to your wished price.