MP120D2 or P120D2 | MP120D4 or P120D4 | MP240D2 or P240D2 | MP240D4 or P240D4 | MP380D4 | |
Nominal AC Line Voltage | 120 | 120 | 240 | 240 | 380 |
Nominal Current Rating (Amps) | 2 | 4 | 2 | 4 | 4 |
1 cycle Surge (Amps) Peak | 20 | 85 | 20 | 85 | 85 |
Nominal Signal Input Resistance (Ohms) | 1000 | 1000 | 1000 | 1000 | 1000 |
Signal Pick-up Voltage | 3VDC*** (24V allowed) | 3VDC*** (24V allowed) | 3VDC*** (24V allowed) | 3VDC*** (24V allowed) | 3VDC*** (24V allowed) |
Signal Drop-out Voltage | 1 VDC | 1 VDC | 1 VDC | 1 VDC | 1 VDC |
Peak Repetitive Voltage Maximum | 600 | 600 | 600 | 600 | 600 |
Maximum Output Voltage Drop | 1.6 volts | 1.6 volts | 1.6 volts | 1.6 volts | 1.6 volts |
Off-State Leakage (mA) Maximum** | 5 mA | 5 mA | 5 mA | 5 mA | 5 mA |
Operating Voltage Range (Volts AC) | 12-140 | 12-140 | 24-280 | 24-280 | 24-420 |
I2t Rating t=8.3 (ms) | 2 | 30 | 2 | 30 | 30 |
Isolation Voltage | 4,000VRMS | 4,000VRMS | 4,000VRMS | 4,000VRMS | 4,000VRMS |
θjc* °C/Watt | 20 | 6.5 | 20 | 6.5 | 6.5 |
Dissipation Watts/Amp | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 |
Rating (Motor Load) | 1 FLA at 120 VAC 6 LRA at 120 VAC | 2.5 FLA at 240 VAC 6 LRA at 240 VAC | 1 FLA at 120 VAC 15 LRA at 120 VAC | 2.5 FLA at 240 VAC 15 LRA at 240 VAC | 2.5 FLA at 380 VAC 15 LRA at 380 VAC |
Notes: θjc* = Thermal resistance junction to base. Maximum junction temperature is 110 °C. ** Operating Frequency: 25 to 65 Hz (operates at 400 Hz with 6 times the offstate leakage) *** = P Series 32 volts maximum. |